Reznor DV Operation Manual (for units built before August Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Grzejniki Reznor DV Operation Manual (for units built before August. no-title Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
NOTICE:
The information contained on the following page(s) was produced
prior to May 1, 2014. On that date Reznor became part of
Nortek, Inc.
References to any other company afliations are no longer valid.
This manual refers to Reznor brand products that have been
discontinued for more than 10 years.
Some replacement parts may no longer be available from
our suppliers. Compatible parts may be substituted.
Please contact your Reznor Representative
with specic questions.
©2014 Reznor, LLC. All Rights Reserved.
Trademark notice: Reznor is registered in at least the United States.
0514 PDF Form Cover2
Przeglądanie stron 0
1 2 3 4 5 6 ... 24 25

Podsumowanie treści

Strona 1 - 0514 PDF Form Cover2

NOTICE:The information contained on the following page(s) was produced prior to May 1, 2014. On that date Reznor became part ofNortek, Inc.References

Strona 2 - SERVICE REFERENCE

Form O-DV/RDF/ADF, P/N 148385, Page 99. Limit SafetyControlsEach unit has an automatic temperature activated limit control, a manual resettemperat

Strona 3 - MAINTENANCE

Form O-DV/RDF/ADF, P/N 148385, Page 10FIGURE 14 - AirPressure Switch10. Air PressureSwitchesLocation: Control Compartment Electrical Box (See FIGU

Strona 4 - Pressure

Form O-DV/RDF/ADF, P/N 148385, Page 1111. Ignition SystemFIGURE 15 - IgnitionControl Module in theElectrical Compartment,P/N 157953FIGURE 16 - Ign

Strona 5

Form O-DV/RDF/ADF, P/N 148385, Page 12FIGURE 20 - ModulatingGas ValveFIGURE 18 - Two-StageGas Valve and DischargeDuctstat in Makeup Air GasControl

Strona 6 - (ADF/ADFH only)

Form O-DV/RDF/ADF, P/N 148385, Page 13lengthening or shortening the flame. The BTU output is varied (modulated) tomaintain the required discharge

Strona 7 - Retainer

Form O-DV/RDF/ADF, P/N 148385, Page 1412. Gas Train (cont'd) Electronic ModulationGas Controls (cont'd)FIGURE 25 -Modulating Gas ValveO

Strona 8 - Guide, Paragraph 20, page 23

Form O-DV/RDF/ADF, P/N 148385, Page 15FIGURE 26 - MaxitrolSeries 14 Components usedin Recirculation Air GasControl Option AG47Return Air Sensor, P

Strona 9 - SERVICE SECTION

Form O-DV/RDF/ADF, P/N 148385, Page 16If the gas train includes either or both high and low gas pressure switches, theswitches monitor gas pressur

Strona 10 - Controls

Form O-DV/RDF/ADF, P/N 148385, Page 1714. Door Switch(Option BX1)FIGURE 31 -Door Switch,P/N 124253Location: The control is installed on an overhea

Strona 11 - Switches

Form O-DV/RDF/ADF, P/N 148385, Page 1815. Inlet Air Controls(cont'd)WARNING: Burnerprofile plates arefactory set to matchCFM requirements. Do

Strona 12

Form O-DV/RDF/ADF, P/N 148385, Page 1FOR YOUR SAFETYWARNING: The use and storage of gasoline or other flammablevapors and liquids in the vicinity

Strona 13 - 12. Gas Train (cont'd)

Form O-DV/RDF/ADF, P/N 148385, Page 19FIGURE 35 -PhotohelicPressureSensor,P/N 159893Photohelic PressureSwitch (automaticbuilding pressure sensor)D

Strona 14

Form O-DV/RDF/ADF, P/N 148385, Page 20FIGURE 37 - PhotoelectricSmoke Detector (coverremoved), P/N 159553, usedwith sampling tube, P/N 159714FIGURE

Strona 15

Form O-DV/RDF/ADF, P/N 148385, Page 2120. TroubleshootingChart 1 - System Troubleshooting (Check the diagnostic lights.)Symptom or Problem Cause a

Strona 16

Form O-DV/RDF/ADF, P/N 148385, Page 22REFERENCE: For service and troubleshooting information on the electrical controls,refer to the manufacturer&

Strona 17 - Arrangements

Form O-DV/RDF/ADF, P/N 148385, Page 23Chart 2 - Troubleshooting Optional Evaporative Cooling Module (Models ADF/ADFH)WARNING: Disconnect the power

Strona 18

Form O-DV/RDF/ADF, P/N 148385, Page 24FOR SERVICE OR REPAIR, FOLLOW THESE STEPS IN ORDER:FIRST: Contact the InstallerName ________________________

Strona 19 - 15. Inlet Air Controls

Form O-DV/RDF/ADF, P/N 148385, Page 2MAINTENANCESECTIONSee Chart oLubricate bearings, Paragraph 1Quarterly oCheck the filters, Paragraph 2oCheck a

Strona 20 - 16. Dirty Filter Switch

Form O-DV/RDF/ADF, P/N 148385, Page 3RES1B. Blower BeltsCheck belts for proper tension and wear. Adjust belt tension as needed. Re-place worn belt

Strona 21

Form O-DV/RDF/ADF, P/N 148385, Page 4SSFIGURE 3 - CircuitIndicator Board,P/N 151263Check bulbs notlit with otherbulbs; replaceany burned outbulbs.

Strona 22 - 20. Troubleshooting

Form O-DV/RDF/ADF, P/N 148385, Page 5FIGURE 4 - Burner EndPlate showing Hot SurfaceIgnitorFlame Sensor(not shown)LocationBurnerEnd Plateburner bod

Strona 23

Form O-DV/RDF/ADF, P/N 148385, Page 66. Replace media by sliding media pads over both support rails until backstop is encountered. Media must be p

Strona 24

Form O-DV/RDF/ADF, P/N 148385, Page 72. Remove the service panel and the junction box door. Disconnect the two-line voltage power supply wires fro

Strona 25 - (800) 695-1901

Form O-DV/RDF/ADF, P/N 148385, Page 8FIGURE 9 - ControlIdentification and TypicalLocations (Model DV isshown as an example)ControlRelaysOutside Ai

Komentarze do niniejszej Instrukcji

Brak uwag